Compares a measured droop against reference C-DC-bias curves at the same case, value and
absolute bias voltage, and reports which ratings remain consistent.
Reading
Match tolerance
A rating stays in the candidate list if the reference band at your bias comes within this many percentage points of your reading.
Fixture offset
Subtracted from every reading before matching. Calibrated on a known 0805 0.1 µF X7R 100 V part: 47.2% measured at 50 V and 73.1% at 90 V, against reference bands of 36.2–42.4% and 64.5–68.9% — a constant +4.5 pt. Most likely AC drive level above the reference 1.0 Vrms. Set to 0 to see raw readings.
DC bias fixture
Bias tee. U1 injects DC while presenting a high impedance to the
measurement; C1 blocks that DC from the LCR meter's terminal. R1 bleeds the DUT down
when the supply is lowered. The ×100 voltmeter reads bias directly across the part —
the drop across U1 means the supply setting is not the DUT voltage.
bold band = candidatefaint = ruled outdashed = X5Ryour reading